Series 65 Conventional Fire Detectors


FEATURES
Designed to meet approvals world-wide
ASICS for increased reliability
Sleek shape – pure white finish
Polarity insensitive
High environmental performance
Easy to clean
Easy to install
Smooth action, one-way-fit base
Series 65 Conventional Fire Detectors

Series 65 is a range of conventional fire detectors, designed for the highest effectiveness by utilising the latest technology. The range comprises ionisation, integrating ionisation and optical smoke detectors and a series of combined rate-of-rise and fixed temperature heat detectors, all with enhanced performance, high reliability and elegant shape.

These detectors have been carefully researched by the Apollo design team and the range has undergone rigorous testing to ensure that it meets not only the European standard but also the demands of today's high-technology environments.

ORDER CODE      DESCRIPTION

BF/C/DET/O S65 Optical Smoke Detector
BF/C/DET/I S65 Ionisation Smoke Detector
BF/C/DET/II S65 Integrating Ionisation Smoke Detector
BF/C/DET/RR S65 Rate-of-Rise Heat Detector
BF/C/DET/H/80 S65 80° Fixed Temperature Heat Detector
BF/C/DET/H/100 S65 100° Fixed Temperature Heat Detector
ORDER CODE      DESCRIPTION

BF/C/BASE S65 Detector Base c/w Diode
BF/C/BASE/R S65 Detector Base c/w Relay

TECHNICAL SPECIFICATIONS
TYPICAL AT 23°C AND 24VDC UNLESS OTHERWISE STATEDSERIES 65 IONISATION (STD./ INTEGR)SERIES 65 OPTICALSERIES 65 GR2 HEAT (65°C)SERIES 65 RANGE 1 HEAT (80°C)SERIES 65 RANGE 2 HEAT (100°C)
Detector Part No.BF/C/DET
/I
BF/C/DET
/O
BF/C/DET
/RR
BF/C/DET
/H/80
BF/C/DET
/H/100
Base Part No.BF/C/BASEBF/C/BASEBF/C/BASEBF/C/BASEBF/C/BASE
Size of Detector
Height x Diameter (mm)
42x10042x10042x10042x10042x100
Size of Detector in Base
Height x Diameter (mm)
50x10050x10050x10050x10050x100
Supply Voltage17–28VDC17–28VDC17–28VDC17–28VDC17–28VDC
Maximum Quiescent Current at 24V45µA45µA53µA53µA53µA
Alarm Current at 24V52mA52mA52mA52mA52mA
Alarm IndicationRed LEDClear LED (Red in Alarm)Red LEDRed LEDRed LED
Normal Operating Temperature
(no icing)
-20°C to +60°C-20°C to +105°C-20°C to +105°C-20°C to +105°C
Humidity (no condensation)0–95%0–95%0–95%0–95%0–95%
Max wind (continuous)10m/sN/AN/AN/AN/A
Remote Output Characteristics900 ohms in series with a 3V drop (suitable for connecting one LED)

Series 65 Mounting Base - part no. BF/C/BASE

Wiring diagram of monitored Series 65 Zone
Note: L1 must be connected to positive line if a remote indicator is connected. An 'EARTH' terminal is provided for zone wiring continuity.


Base Lighting and Fire Ltd reserve the right to change specifications without prior notification.
All specifications and details are given in good faith but Base Lighting and Fire Ltd cannot be held responsible for any errors or omissions on this website

© 2005 Base Lighting and Fire Ltd





Home
Contact Us
Fire Alarm System Design
Emergency Lighting System Design
Fire Alarm Catalogue
Conventional Fire Equipment
  C100
  C200
  Series 65
  Orbis
  Multiflex
Analogue Fire Equipment
Emergency Lighting Catalogue
Disability Catalogue